Brocade Communications Systems Brocade 8/12c Reference page 128

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

5
Physical entity group
Object and OID
entPhysicalClass
1.3.6.1.2.1.47.1.1.1.1.5
(continued)
108
Access
Description
Read only
Brocade DCX directors can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs,
four power supplies, three fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade DCX-4S directors can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (four port blades, two CPs,
two power supplies, two fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade 12000, 24000, and 48000 directors can have the following
hierarchy of physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs,
four power supplies, three fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade 3900 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, six fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to six entries for fans
Brocade 4100 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, three fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to three entries for fans
Brocade 7500 and 7600 switches can have the following hierarchy of
physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, three fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to three entries for fans
Brocade 8000 switch can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, three fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to three entries for fans