9
Connectivity unit group
Object and OID
connUnitSensorMessage
1.3.6.1.3.94.1.8.1.6
connUnitSensorType
1.3.6.1.3.94.1.8.1.7
connUnitSensorCharacte
ristic
1.3.6.1.3.94.1.8.1.8
connUnitPortTable
1.3.6.1.3.94.1.10
connUnitPortEntry
1.3.6.1.3.94.1.10.1
connUnitPortUnitId
1.3.6.1.3.94.1.10.1.1
208
Access
Description
Read only
This describes the status of the sensor as a message. It may also
provide some information about the sensor, for example:
sensor 1: type 3 is OK, value is 33
Each contains the sensor status (and reading if applicable) in textual
format.
Read only
The type of component being monitored by this sensor.
Possible values are:
•
unknown (1)
•
other (2)
•
battery (3)
•
fan (4)
•
power-supply (5)
•
transmitter (6)
•
enclosure (7)
•
board (8)
•
receiver (9)
The following mapping is for each individual sensor, where applicable:
swSensorType
1 (temperature)
2 (fan)
3 (power supply)
Read only
The characteristics being monitored by this sensor.
The following mapping is for each individual sensor, where applicable:
swSensorType
1 (temperature)
2 (fan)
3 (power supply)
Possible values are:
•
unknown (1)
•
other (2)
•
temperature (3)
•
pressure (4)
•
emf (5)
•
currentValue (6) Current is a keyword.
•
airflow (7)
•
frequency (8)
•
power (9)
•
door (10) - Not supported in Fabric OS v2.6.1.
Not
Generic information on ports for a specific connUnit
accessible
NOTE: Information about the GbE ports on a Brocade 7500 or FR4-18i
blade is not supported.
Not
Each entry contains the information for a specific port.
accessible
Read only
The connUnitId value of the connectivity unit that contains this port.
Same value as connUnitId.
connUnitSensorType
8 (board)
4 (fan)
5 (power supply)
connUnitSensorCharacteristic
3 (temperature)
7 (airflow)
9 (power)
Fabric OS MIB Reference
53-1002151-01