6
Switch system group
Object and OID
swBeaconAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.1.19
swDiagResult
1.3.6.1.4.1.1588.2.1.1.1.1.20
swNumSensors
1.3.6.1.4.1.1588.2.1.1.1.1.21
swSensorTable
1.3.6.1.4.1.1588.2.1.1.1.1.22
swSensorEntry
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1
swSensorIndex
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.1
swSensorType
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.2
swSensorStatus
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.3
142
Access
Description
Read-write
The desired status of the switch beacon.
Possible values are:
on (1) - The LEDs on the front panel of the switch run
alternately from left to right and right to left. Set the color to
yellow.
off (2) - Set each LED to its regular status, indicating color and
state.
Read only
The result of the power-on startup test (POST) diagnostics.
Possible values are:
sw-ok (1) - The switch is okay.
sw-faulty (2) - The switch has experienced an unknown fault.
sw-embedded-port-fault (3) - The switch has experienced an
embedded port fault.
Read only
The number of sensors inside the switch.
The Brocade DCX value is between 1 and 57 (temperature =50, fan
= 3, power supply = 4). The value might vary depending on the
switch model. For Fabric OS v6.1.0, if no sensor is available, this
variable is assigned the value -1.
Not
Table of sensor entries.
accessible
Table 16
lists the sensors on the Brocade switches.
The sensors on the switches vary based on the blades. For the
exact count of temperature sensors, refer to
Not
An entry of the sensor information.
accessible
Read only
The index of the sensor.
The values are 1 through the value in swNumSensors
Read only
The type of sensor.
Read only
The current status of the sensor.
Possible values are:
unknown (1)
faulty (2)
below-min (3) - The sensor value is below the minimal
threshold.
nominal (4)
above-max (5) - The sensor value is above the maximum
threshold.
absent (6) - The sensor is missing.
For Temperature, valid values include 3 (below-min), 4 (nominal),
and 5 (above-max).
For Fan, valid values include 3 (below-min), 4 (nominal), and 6
(absent).
For Power Supply, valid values include 2 (faulty), 4 (nominal), and 6
(absent).
Table
17.
Fabric OS MIB Reference
53-1002151-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0