fcFeOp group
Object and OID
fcFxPortPhysOperStatus
1.3.6.1.3.42.2.1.2.3.1.4
fcFxPortPhysLastChange
1.3.6.1.3.42.2.1.2.3.1.5
fcFxPortPhysRttov
1.3.6.1.3.42.2.1.2.3.1.6
fcFxlogiTable
1.3.6.1.3.42.2.1.2.4
fcFxlogiEntry
1.3.6.1.3.42.2.1.2.4.1
fcFxlogiModuleIndex
1.3.6.1.3.42.2.1.2.4.1.1
fcFxlogiFxPortIndex
1.3.6.1.3.42.2.1.2.4.1.2
fcFxlogiNxPortIndex
1.3.6.1.3.42.2.1.2.4.1.3
fcFxPortFcphVersionAgree
d
1.3.6.1.3.42.2.1.2.4.1.4
fcFxPortNxPortBbCredit
1.3.6.1.3.42.2.1.2.4.1.5
fcFxPortNxPortRxDataFiel
dSize
1.3.6.1.3.42.2.1.2.4.1.6
fcFxPortCosSuppAgreed
1.3.6.1.3.42.2.1.2.4.1.7
96
Access
Description
Read only
The current operational status of the Fx_Port:
online (1) Log in might proceed.
offline (2) Log in cannot proceed.
testing (3) Port is under test.
link-failure (4) Failure after online/testing.
The testing state (3) indicates that no operational frames can be
passed. If fcFxPortPhysAdminStatus is offline (2), then
fcFxPortPhysOperStatus should be offline (2). If
fcFxPortPhysAdminStatus is changed to online (1), then
fcFxPortPhysOperStatus should change to 1 (online) if the Fx_Port is
ready to accept fabric login request from the attached Nx_Port; it should
proceed and remain in the link-failure state (4) if and only if there is a
fault that prevents it from going to the online state (1).
Read only
The value of sysUpTime at the time the Fx_Port entered its current
operational status. A value of 0 indicates that the Fx_Port's operational
status has not changed since the agent last restarted.
Read only
The Receiver_Transmitter_Timeout value of the Fx_Port. This is used by
the receiver logic to detect Loss of Synchronization.
Not
This table contains one entry for each Fx_Port in the fabric element, and
accessible
the Service Parameters that have been established from the most
recent fabric login, whether implicit or explicit.
Not
An entry containing service parameters established from a successful
accessible
fabric login.
Read only
Identifies the module containing the Fx_Port for which this entry
contains information.
Read only
Identifies the Fx_Port within the module. This number ranges from 1 to
the value of fcFeModulePortCapacity for the associated module. The
value remains constant for the identified Fx_Port until the module is
re-initialized.
Read only
The object identifies the associated Nx_Port in the attachment for which
the entry contains information.
Read only
The version of FC-PH that the Fx_Port has agreed to support from the
fabric login.
Read only
The total number of buffers available for holding Class 1
connect-request Class 2 or Class 3 frames to be transmitted to the
attached Nx_Port. It is for buffer-to-buffer flow control in the direction
from Fx_Port to Nx_Port. The buffer-to-buffer flow control mechanism is
indicated in the respective fcFxPortBbCreditModel.
Read only
The Receive Data Field Size of the attached Nx_Port. This is a binary
value that specifies the largest Data Field Size for an FT_1 frame that
can be received by the Nx_Port. The value is a number of bytes in the
range 128 to 2112, inclusive.
Read only
Indicates that the attached Nx_Port has requested the Fx_Port for the
support of classes of services and the Fx_Port has granted the request.
Fabric OS MIB Reference
53-1002151-01