Brocade Communications Systems Brocade 8/12c Reference page 161

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

Object and OID
swFlashDLAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.1.12
swFlashDLHost
1.3.6.1.4.1.1588.2.1.1.1.1.13
swFlashDLUser
1.3.6.1.4.1.1588.2.1.1.1.1.14
swFlashDLFile
1.3.6.1.4.1.1588.2.1.1.1.1.15
swFlashDLPassword
1.3.6.1.4.1.1588.2.1.1.1.1.16
swBeaconOperStatus
1.3.6.1.4.1.1588.2.1.1.1.1.18
Fabric OS MIB Reference
53-1002151-01
Access
Description
Read-write
The desired state of the flash.
The host is specified in swFlashDLHost.0. In addition, the user
name is specified in swFlashDLUser.0 and the file name specified
in swFlashDLFile.0.
Possible values are:
swCurrent (1) - The flash contains the current firmware image
or configuration file.
swCfUpload (3) - The switch configuration file is to be
uploaded to the host specified.
swCfDownload (4) - The switch configuration file is to be
downloaded from the host specified.
swFwCorrupted (5) - The firmware in the flash is corrupted.
This value is for informational purposes only; however, setting
swFlashDLAdmStatus to this value is not allowed.
For more information about the firmwareDownload,
configDownload and configUpload commands, refer to the Fabric
OS Command Reference.
Read-write
The name or IP address (in dot notation) of the host to download or
upload a relevant file to the flash.
This OID cannot be used for either firmwareDownload or
configDownload (cannot be set and is read only) for Fabric OS v4.4
and later. The value displayed is always NULL (zero-length).This is
not supported in Fabric OS v6.0.0 and later versions.
Read-write
The user name is used on the host for downloading or uploading a
relevant file, to or from the flash.
This OID cannot be used for either firmwareDownload or
configDownload (cannot be set and is read only) for Fabric OS v4.4
and later. The value displayed is always NULL (zero-length).This is
not supported in v6.0.0 and later versions.
Read-write
The name of the file to be downloaded or uploaded.
This OID cannot be used for either firmwareDownload or
configDownload (cannot be set and is read only) for Fabric OS v4.4
and later. The value displayed is always NULL (zero-length).This is
not supported in v6.0.0 and later versions.
Read-write
The password to be used for FTP transfer of files in the download or
upload operation.
This OID cannot be used for either firmwareDownload or
configDownload (cannot be set and is read only) for Fabric OS v4.4
and later. The value displayed is always NULL (zero-length).This is
not supported in v6.0.0 and later versions.
Read only
The current operational status of the switch beacon.
Possible values are:
on (1) - The LEDs on the front panel of the switch run
alternately from left to right and right to left. The color is
yellow.
off (2) - Each LED is in its regular status, indicating color and
state.
Switch system group
6
141