6
Fabric Watch group
Object and OID
swFwWriteThVals
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.2
swFwDefaultUnit
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.3
swFwDefaultTimebase
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.4
swFwDefaultLow
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.5
swFwDefaultHigh
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.6
swFwDefaultBufSize
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.7
swFwCustUnit
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.8
swFwCustTimebase
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.9
swFwCustLow
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
0
swFwCustHigh
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
1
swFwCustBufSize
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
2
158
Access
Description
Read-write This applies or cancels the configuration value changes.
For a read operation, the return value is always
swFwCancelWrite.
The following custom configuration variables can be modified:
swFwCustUnit
swFwCustTimebase
swFwCustLow
swFwCustHigh
swFwCustBufSize
Changes to these custom configuration variables can be saved
by setting this variable to swFwApplyWrite; they can be removed
by setting this variable to swFwCancelWrite.
Read only
A default unit string name, used to identify the unit of measure
for a Fabric Watch classArea combination.
C = environment (class), temperature (area).
RPM = environment (class), fan (area).
Read only
A default polling period for the Fabric Watch classArea
combination.
swFwTbMin = port (class), link loss (area).
swFwTbNone = environment (class), temperature (area).
Read only
A default low threshold value.
Read only
A default high threshold value.
Read only
A default buffer size value.
Read only
A customizable unit string name, used to identify the unit of
measure for a Fabric Watch classArea combination.
C = environment (class), temperature (area).
RPM = environment (class), fan (area).
Read-write A customizable polling period for the Fabric Watch classArea
combination.
swFwTbMin = port (class), link loss (area).
swFwTbNone = environment (class), temperature (area).
Read-write A customizable low-threshold value for a Fabric Watch classArea
combination.
Read-write A customizable high-threshold value for a Fabric Watch
classArea combination.
Read-write A customizable buffer size value for a Fabric Watch classArea
combination.