Object and OID
connUnitControl
1.3.6.1.3.94.1.6.1.22
connUnitContact
1.3.6.1.3.94.1.6.1.23
connUnitLocation
1.3.6.1.3.94.1.6.1.24
connUnitEventFilter
1.3.6.1.3.94.1.6.1.25
connUnitNumEvents
1.3.6.1.3.94.1.6.1.26
connUnitMaxEvents
1.3.6.1.3.94.1.6.1.27
connUnitEventCurrID
1.3.6.1.3.94.1.6.1.28
connUnitRevsTable
1.3.6.1.3.94.1.7
206
Access
Description
Read-write
Controls the addressed connUnit. Each implementation might choose
not to allow any or all of these values on a SET.
Cold start and warm start are as defined in MIB-II and are not meant to
be a factory reset.
This is similar to swAdmStatus:
resetConnunitColdStart = reboot
resetConnunitWarmStart = fastboot
offlineConnUnit = disable switch
onlineConnUnit = enable switch
default after reboot = unknown
The declaration 1 (unknown) maps to the default value upon rebooting,
and 2 (invalid) is not applicable.
Declarations 3 and 4 perform the same operation—a cold boot of the
switch.
Possible values are:
unknown (1)
invalid (2)
resetConnUnitColdStart (3): Reboot. Performs a switch reboot.
resetConnUnitWarmStart (4): Fastboot. The addressed unit
performs a Warm Start reset.
offlineConnUnit (5): Disable switch. The addressed unit puts itself
into an implementation-dependant offline state. In general, if a unit
is in an offline state, it cannot be used to perform meaningful Fibre
Channel work.
onlineConnUnit (6): Enable switch. The addressed unit puts itself
into an implementation-dependant online state. In general, if a unit
is in an online state, it is capable of performing meaningful Fibre
Channel work.
Read-write
Contact information for this connectivity unit.
Displays the same value as sysContact. Changing the value in this
variable causes the value in sysContact to also be changed.
Read-write
Location information for this connectivity unit.
Displays the same value as sysLocation.
Read only
Defines the event severity logged by this connectivity unit. All events of
severity less than or equal to connUnitEventFilter are logged in
connUnitEventTable.
Always returns value 9 (debug).
Read only
Number of events currently in connUnitEventTable.
Fabric OS currently supports 1024 raslog events.
Read only
Maximum number of events that can be defined in connUnitEventTable.
This value ranges from 0 to 1024.
Read only
The last-used event ID (connUnitEventId). Every RASLOG message has
RASLOG number and this represents the RASLOG number.
Maximum is 2147483647 (2
Not
Table of the revisions supported by connectivity units managed by this
accessible
agent.
Usage Notes This table lists the versions of hardware and software
elements in the switch.
One entry for the hardware platform version and another entry for the
Fabric OS version. For example, for the Brocade 4100 the hardware
platform number is 32.0. The Fabric OS version for this release is 5.1.
31
-1).
Fabric OS MIB Reference
53-1002151-01