Error is informed by means of the panel display and control box buzzer.
Three dfferent knds of screens of the panel dsplay screen appear due to the dfference of the procedures.
[Error code list (Error display in panel) ]
There are the followng error codes n ths devce. These error codes nterlock (or lmt functon) and nform the problem
so that the problem is not enlarged when any problem is discovered. When you request our service, please confirm the
error codes.
No.
Descrpton of error detected
Meda cover open
E000
Executon of data ntalzaton
(Ths s not the error.)
E003
Dsconnecton of
synchronzer connector
E004
Synchronzer lower poston
sensor falure
E005
Synchronzer upper poston
sensor falure
E007
Overload of motor
E00
Machne head connector
falure (Resstance pack)
E0
Meda s not nserted.
E02
Read error
E03
Wrte error
E04
Wrte protect
E05
Format error
E06
External meda capacty over
E09
Fle sze over
E032
Fle nterchangeablty error
E053
Executon of panel backup
data ntalzaton (Not error)
) Error screen dsappears when the operator removes the cause.
Example) Cover of the slot of meda s open. Close the cover.
2) Press the reset swtch, and remove the cause of error after erasng the
error screen.
3) Remove the cause of error after turnng OFF the power.
Cause of occurrence expected
• Cover of the slot of meda s open.
• When the machne head s changed.
• When the ntalzaton operaton s executed.
• When poston detecton sgnal s not nput
from the sewng machne head synchronzer.
• When the synchronzer has broken.
• When the machne head s locked.
• When sewng extra-heavy materal beyond
the guarantee of the machne head.
• When the motor does not run.
• Motor or drver s broken.
• When the machne head connector s not
properly read.
• Meda s not nserted.
• Data of meda cannot be read.
• Data of meda cannot be wrtten.
• Meda s n the state of wrtng prohbton.
• Formattng cannot be performed.
• Capacty of meda s short.
• Fle s too large.
• There is no interchangeability of file.
• When model code of panel does not agree
wth that of control box.
When executng ntalzaton operaton wth
the panel.
– 47 –
Items to be checked
• Close the cover.
• Check the synchronzer connector
(CN33, CN43) for loose connecton and
dsconnecton.
• Check whether the synchronzer cord has
broken snce the cord s caught n the
machne head.
• Check whether the thread has been
entangled n the motor pulley.
• Check the motor output connector (4P) for
loose connecton and dsconnecton.
• Check whether there s any holdup when
turnng the motor by hand.
• Check the machne head connector (CN32)
for loose connecton and dsconnecton.
• Turn OFF the power.
• Turn OFF the power.
• Turn OFF the power.
• Turn OFF the power.
• Turn OFF the power.
• Turn OFF the power.
• Turn OFF the power.
• Turn OFF the power.