JUKI IP-110 Instruction Manual page 37

For sewing machine
Hide thumbs Also See for IP-110:
Table of Contents

Advertisement

[Output function list]
When setting output function to output connector CN50, do not apply voltage exceeding the value set
with W1 and W2 (jumpers for power voltage) to the optional output terminal. When voltage exceeding
the setting is applied, there is the possibility that breakage or deterioration of circuit board occurs.
So, be careful. For the details, refer to the Engineer's Manual for SC-510.
Functon dsplay
Functon code No.
No functon settng
0
Thread trmmng output

Wper output
2
Tenson release output
3
Presser lfter output
4
Reverse sttchng output
5
Reverse sttchng at end
once cancel montor output
6
Reverse sttchng at start/
end cancel montor output
7
Cancel/addton of
automatc reverse sttchng
swtch montor output

Alternate vertcal movement
amount change (montor)
output
9
Sewng machne stop state
output
0
2-ptch (montor) output

Center gude output
2
Needle cooler output
3
Functon name
: L output
: L output
: L output
: L output
: L output
: L output
: L output
: L output
: L output
: L output
: L output
: L output
: L output
Input state settng
(Standard settng)
-
Ths functon outputs thread trmmng sgnal.
(When ths functon s selected, functon
correspondng to connectors for sewng machne
: H output
(CN36, CN37) becomes nvald.)
Ths functon outputs wper sgnal. (When ths
functon s selected, functon correspondng to
connectors for sewng machne (CN36, CN37)
: H output
becomes nvald.)
Ths functon outputs tenson release sgnal.
(When ths functon s selected, functon
correspondng to connectors for sewng machne
: H output
(CN36, CN37) becomes nvald.)
Ths functon outputs presser lfter sgnal. (When
ths functon s selected, functon correspondng
to connectors for sewng machne (CN36,
: H output
CN37) becomes nvald.)
Ths functon outputs reverse sttchng sgnal.
(When ths functon s selected, functon
correspondng to connectors for sewng machne
: H output
(CN36, CN37) becomes nvald.)
Ths functon outputs reverse sttchng at end
once cancel functon state.
: H output
Ths functon outputs reverse sttchng at start
and/or end cancel functon state.
: H output
Ths functon outputs cancel/addton of
automatc reverse sttchng swtch nput state.
: H output
T h  s f u n c t  o n o u t p u t s a l t e r n a t e v e r t  c a l
movement amount change sgnal.
: H output
Ths functon outputs sewng machne stop
state.
: H output
Ths functon outputs 2-ptch sgnal.
: H output
Ths functon outputs center gude sgnal.
: H output
Ths functon outputs the sgnal for needle
cooler.
: H output
– 35 –
Descrpton of functon

Advertisement

Table of Contents
loading

Table of Contents