EPSON Stylus Pro 3800/3800C/3850
6.
Remove the HARNESS, ENCODER, PF secured to the MOTOR, RELEASE,
ASSY., with the two-sided tape.
7.
Remove the three screws that secure the MOTOR, RELEASE, ASSY.
See Figure 4-105.
Three C.B.S. 3 x 6 screws (9 ± 1 kgf.cm)
8.
Remove the TIMING BELT, PF from the pinion gear of the MOTOR ASSY., PF
and remove the MOTOR, RELEASE, ASSY.
Whenever the MOTOR, RELEASE, ASSY., is replaced,
the corresponding adjustments must be carried out.
See Chapter 5
"ADJUSTMENT"
Left side of the printer
Two-sided Tape
Figure 4-104. Removing the HARNESS, ENCODER, PF
DISASSEMBLY & ASSEMBLY
See Figure 4-104.
(p190).
MOTOR, RELEASE, ASSY.
HARNESS, ENCODER, PF
Disassembly/Assembly Procedure (Group 1)
C.B.S. 3x6
C.B.S. 3x6
Figure 4-105. Removing the screws from the MOTOR, RELEASE ASSY.
Revision A
C.B.S. 3x6
MOTOR, RELEASE, ASSY.
TIMING BELT, PF
168