BMC firmware
This update is in the form of a bootable diskette. If you have the RSA II
configured and connected to your network, you can use the Remote Console
feature with a remote diskette and boot each node from the diagnostics diskette.
On x3950 M2 multinode complex, if you perform the update from the primary
node, then all other nodes are automatically updated as shown in Example 5-2.
Example 5-2 Updating the BMC code on a two-node complex
Detecting RAMDRIVE
Copying files to RAMDRIVE D:
Decompressing BMC firmware
reading fullfw.cmt...wrote 16360 SRECs to fullfw.mot
Acquiring BMC attributes
Updating BMC Firmware
Do you want to clear the SEL (y or n)?y
> SEL Cleared.
>
Flash Loader v1.30.0.54, OSA Technologies. Inc. (c)2007
IPMI Version=
major Revision=
minor Revision =
manufacturer ID =
product ID=
build Name=
Firmware and the image have the same version and build name.
Start to program flash? (Y/N) Y_
Start programming...
Writing to Address: 0x0007FF80......OK.
Download to Flash OK.
BMC initialization...OK.
BMC Firmware and SDRs updated successfully!!!
Do you want to clear the SEL (y or n)?y
> SEL Cleared.
>
Flash Loader v1.30.0.54, OSR Technologies. Inc. (c)2007
IPMI Version=
250
Planning, Installing, and Managing the IBM System x3950 M2
firmware
image
2.0
2.0
2
2
32
32
2
2
77
77
A3BT31B
A3BT31B
firmware