Secondary nodes:
E Merge Failure-Timeout occurred waiting for primary server.
I System Complex Powered Up
Ensure that no hardware error occurred. See Figure 4-31. In the RSA II Web
interface, select Monitors → Event Log at each node in this partition.
Figure 4-31 RSA II Web interface - Event log selection
Check the Severity column to determine if any events are colored with red or
yellow at this specific time frame (see Figure 4-32). You can filter the events at
Severity, Source, and Date.
Figure 4-32 RSA II Web interface: event log filtering
How to resolve the problem
To resolve the problem, try the following steps:
1. Power off both systems and start the multinode again. If the scalability
management menu is unresponsive, perform a power off at all systems in this
partition in the power options of the RSA II Web interface. See Figure 4-30 on
page 233.
2. Perform an AC power cycle and wait 30 seconds before you replug the power
cables. Try a merge.