Ethernet Controller Messages; Novell Netware Or Intranetware Server Odi Driver Messages - IBM 866631Y - Netfinity 7100 - 8666 Hardware Maintenance Manual

Hardware maintenance manual
Table of Contents

Advertisement

Table 2. Ethernet troubleshooting chart (continued)
Ethernet controller
problem
The Ethernet controller
stopped working
without apparent cause.

Ethernet controller messages

The integrated Ethernet controller might display messages from the following
device drivers:
v Novell
NetWare
v NDIS Adapter for level 4.0 (Windows NT)
v SCO
UNIX LLI

Novell NetWare or IntraNetWare server ODI driver messages

This section provides explanations of the error messages for the Novell NetWare or
IntraNetWare server ODI driver, and suggested actions to resolve each problem.
Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller
PCNTNW-NW-026 The MSM is unable to parse a required custom keyword.
PCNTNW-NW-054 The adapter did not respond to the initialization command.
PCNTNW-NW-058 The adapter did not respond to the initialization command.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
PCNTNW-NW-071 The matching virtual adapter could not be found.
Suggested Action
Check the following:
v Run diagnostics for the Ethernet controller.
v Try a different connector on the hub.
v Reinstall the device drivers. Refer to the operating-system
documentation and to the ServerGuide information.
or IntraNetWare Server ODI
Explanation: The user entered an incorrect parameter keyword.
Action: Reload the driver using the correct keyword.
Explanation: The adapter did not respond when the driver tried to
initialize it. Action: Verify that the Ethernet controller is enabled. If
the Ethernet controller is enabled, go to "Starting the diagnostic
programs" on page 14 to run the diagnostic programs.
Explanation: The interrupt request (IRQ) setting might not be valid
or the EEPROM information might be incorrect. Action:Make sure
the IRQ settings are correct in the Configuration/Setup Utility
program. for information on setting the interrupt requests. If the
IRQ settings are correct, go to "Starting the diagnostic programs"
on page 14 to run the diagnostic programs.
Explanation: The cable might be disconnected from the server
Ethernet port. Action: Verify that a cable is connected to the
Ethernet port.
Explanation: You tried to load another instance of the driver with
a different I/O address. This new adapter could not be found.
Action: Verify that you installed an IBM Netfinity 10/100 Fault
Tolerant Adapter and make sure that the adapter is seated
correctly. If the adapter is seated correctly, go to "Starting the
diagnostic programs" on page 14 to run the diagnostic programs.