IBM 866631Y - Netfinity 7100 - 8666 Hardware Maintenance Manual page 131

Hardware maintenance manual
Table of Contents

Advertisement

Beep/Symptom
FRU/Action
3-1-3(RAM test
1. DIMM
failed above
2. Memory card
address OFFFF h))
3. Processor/PCI board
4. I/O Legacy board
3-1-4(Time-Of-Day
1. Battery
clock failed)
2. I/O Legacy Board
3-2-1(Serial port
1. I/O Legacy board
failed)
3-2-2(Parallel port
1. I/O Legacy board
failed)
3-2-3(Math
1. Optional processor (if installed)
coprocessor failed)
2. Processor
3. Processor/PCI board
3-2-4(Failure
1. DIMM
comparing CMOS
2. Processor/PCI board
memory size
3. Battery
against actual)
4. I/O Legacy board
3-3-1(Memory size
1. DIMM
mismatch occurred,
2. Processor/PCI board
see "Memory
3. Battery
Settings" on page
34)
3-3-2(Critical
1. Disconnect the server power cord from outlet, wait 30 seconds
SMBUS error
and retry.
occurred)
2. I/O Legacy Board
3. Processor/PCI Board
4. DIMMs
5. Memory Card
6. DASD Backplane
7. Power Supply
8. Power Supply Backplane
9. 12C Cable
3-3-3(No
1. Install or reseat the memory modules, then power-on the system
operational
(see"Using the Configuration/Setup Utility program" on
memory in system)
page 31).
2. If problem persists, restart the system 3 times.
Note: Restarting the system three times will load default settings.
3. DIMMs
4. Memory Board
5. Processor/PCI Board
6. I/O Legacy Board
Two Short
1. Run Diagnostics
Beeps(Information
2. Run Configuration/Setup
only, the
configuration has
changed)
121