IBM 866631Y - Netfinity 7100 - 8666 Hardware Maintenance Manual page 139

Hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
217-XXX-007 (Failed
BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical array.
217-XXX-008 (Failed
BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical array.
217-XXX-009 (Failed
BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical array.
264-XXX-0NN (NN =
SCSI ID of failing Tape
Drive)
264-XXX-999 (Errors on
multiple tape drives,
see error text for more
info)
301-XXX-000 (Failed
Keyboard test)
405-XXX-000 (Failed
Ethernet test on
controller on the I/O
Legacy Board)
405-XXX-00N (Failed
Ethernet test on adapter
in PCI slot N)
Note: Insure modem is
present and attached to
server.
415-XXX-000 (Failed
Modem test)
FRU/Action
1. Fixed Disk 8
1. Fixed Disk 9
1. Fixed Disk 10
1. Tape Cartridge, if user executed the Read/Write Tape Drive
test (XXX = 256)
2. SCSI or power cable connected to the tape drive with SCSI ID
NN
3. Tape drive with SCSI ID NN – refer to Help and Service
Information appendix of tape drive's User Guide.
4. I/O Legacy Board or SCSI Controller – run SCSI Controller
diagnostic to determine of SCSI bus is functioning properly.
1. See error messages/text in the PC Doctor error log for
detailed information on each individual tape drive error.
1. Keyboard
1. Verify that Ethernet is not disabled in BIOS.
2. I/O Legacy Board
1. Adapter in PCI slot N.
2. I/O Legacy Board
1. Cable
2. Modem
3. I/O Legacy Board
129