134
Hardware Maintenance Manual: Netfinity 7100 – Type 8666
Error Code/Symptom
11XX (System board serial port
1 or 2 error)
1301 (cable to front panel not
found)
1302 (cable from system board
to power on and reset switches
not found)
1303 (cable from system board
to power backplane not found)
1304 (cable to diagnostic LED
board not found)
1600 (The Service Processor is
not functioning) Do the
following before replacing a
FRU:
1. Ensure that a jumper is not
installed on J51.
2. Remove the ac power to the
system, wait 20 seconds;
then, re-connect the ac
power. Wait 30 seconds;
then, power-on the system.
1601 (The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond at
the start of POST.) Do the
following before replacing a
FRU:
1. Remove the ac power to the
system, wait 20 seconds;
then, re-connect the ac
power. Wait 30 seconds;
then, power-on the system.
2. Flash update the Service
Processor.
1762 (Fixed Disk Configuration
error)
FRU/Action
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. I/O Legacy Board
1. Cable
2. Front Panel
3. Power Switch Assembly
4. I/O Legacy Board
1. Cable
2. Power Switch Assembly
3. I/O Legacy Board
1. Cable
2. Power Backplane
3. I/O Legacy Board
1. Cable
2. Diagnostic LED Board
3. Power Switch Assembly
4. I/O Legacy Board
1. I/O Legacy Board
2. Processor/PCI Board
1. I/O Legacy Board
2. Processor/PCI Board
1. Fixed Disk Drive
2. Fixed Disk Cables
3. Run Configuration/Setup
4. Fixed Disk Adapter
5. SCSI Backplane
6. I/O Legacy Board