126
Hardware Maintenance Manual: Netfinity 7100 – Type 8666
Error Code/Symptom
020-XXX-004 (Failed
Hot-Swap Slot 4 PCI
Latch test)
030-XXX-000 (Failed
Internal SCSI interface
test)
030-XXX-00N (Failed
SCSI test on PCI slot N.
Check system error log
before replacing a FRU.)
035-XXX-099
035-XXX-S99 (Failed
RAID test on PCI slot S.
S = number of failing
PCI slot. Check System
Error Log before
replacing a FRU.)
035-XXX-SNN (Check
System Error Log before
replacing a FRU. S =
number of failing PCI
slot; NN = SCSI ID of
failing fixed disk.)
035-253-S99 (RAID
adapter initialization
failure)
075-XXX-000 (Failed
Power Supply test)
089-XXX-001 (Failed
Microprocessor test)
089-XXX-002 (Failed
Optional
Microprocessor test)
089-XXX-003 (Failed
Optional
Microprocessor test)
089-XXX-004 (Failed
Optional
Microprocessor test)
FRU/Action
1. PCI Hot-Swap Latch Assembly
2. Processor/PCI Board
1. I/O Legacy Board
1. Adapter
1. No adapters were found.
2. If adapter is installed re-check connection.
1. Cable
2. SCSI Backplane
3. Adapter
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot
S.
1. ServeRAID Adapter in slot S is not configured properly.
Obtain the basic and extended configuration status and refer
to the ServeRAID Hardware Maintenance Manual for more
information.
2. Cable
3. SCSI Backplane
4. Adapter
1. Power Supply
1. VRM for Microprocessor 1
2. Microprocessor
1. VRM for Optional Microprocessor 2
2. Optional Microprocessor
1. VRM for Optional Microprocessor 3
2. Optional Microprocessor
1. VRM for Optional Microprocessor 4
2. Optional Microprocessor