Hardware Maintenance Manual: Netfinity 7100 – Type 8666
Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller (continued)
PCNTNW-NW-072 A resource tag is unavailable.
Explanation: The driver tried to allocate some resources that were
not available. Action: Add more memory, or free some memory
resources in the server. Then, restart the server.
PCNTNW-NW-073 Unable to allocate memory
Explanation:The driver failed to allocate the memory needed for
normal operation. Action: Add more memory, or free some
memory resources in the server. Then, restart the server.
PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware
interrupt. The attempt was not successful. Action:Verify that the
Ethernet controller is enabled. If the Ethernet controller is enabled,
go to "Starting the diagnostic programs" on page 14 to run the
diagnostic programs.
If you have an Ethernet adapter installed, make sure that the
adapter does not share an IRQ with any other device.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered
with the Link Support Layer (LSL).
Explanation: An error occurred while the driver was trying to
register with the LSL. Action: Check the version of the NetWare or
IntraNetWare Operating System. Make sure that this driver is
correct for the version of NetWare or IntraNetWare that you are
using. Restart the server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize
MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation:The driver parameter block is too small. Action:
Restart the server. If the problem persists, go to "Starting the
diagnostic programs" on page 14 to run the diagnostic programs.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The driver media parameter block is too small.
Action: Restart the server. If the problem persists, go to "Starting
the diagnostic programs" on page 14 to run the diagnostic
programs.
PCNTNW-NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new frame type for the existing
controller. The hardware assumptions made in doing so are
incorrect. This error can also occur if you try to specify a mode
(such as, redundancy) that conflicts with another specified mode.
Action: Make sure that your hardware configuration matches the
software settings.