Power checkout

Power problems can be difficult to troubleshoot. For instance, a short circuit can
exist anywhere on any of the power distribution busses. Usually a short circuit will
cause the power subsystem to shut down because of an overcurrent condition.
A general procedure for troubleshooting power problems is as follows:
1. Power off the system and disconnect the AC cord(s).
2. Check for loose cables in the power subsystem. Also check for short circuits, for
3. Remove adapters and disconnect the cables and power connectors to all
4. Reconnect the AC cord and power on the system. If the system powers up
To use this method it is important to know the minimum configuration required
for a system to power up (see page 131). For specific problems, see "Power error
messages" on page 139.
Table 1. Light path diagnostics (continued)
LED
Cause
FAN
One of the fan assemblies has
failed or is operating too
slowly.
Note: A failing fan can also
cause the TEMP and DASD
LEDs to be on.
TEMP
The system temperature has
exceeded the maximum rating.
NON RED Server drawing too much
power to operate in a
redundant power mode.
OVER
The server is drawing more
SPEC
power than the power
supplies are rated for.
PS1
The first power supply has
failed.
PS2
The second power supply has
failed.
PS3
The third power supply has
failed.
PS4
The fourth power supply has
failed.
instance if there is a loose screw causing a short circuit on a circuit board.
internal and external devices until system is at minimum configuration
required for power on (see "Minimum operating requirements" on page 131).
successfully, replace adapters and devices one at a time until the problem is
isolated. If system does not power up from minimal configuration, replace
FRUs of minimal configuration one at a time until the problem is isolated.
Action
The LED on the failing fan assembly will be
lit. Replace the fan assembly.
1. Check to see if a fan has failed. If it has,
replace the fan.
2. Make sure the room temperature is not
too high. (See "Temperature checkout" on
page 20.)
If the problem persists, see "Diagnostic panel
LEDs" on page 122.
System can continue to operate in a
nonredundant power mode. To operate in a
redundant mode, add a power supply or
remove most recently installed options.
Either add a power supply or remove a
device from the server.
Replace the first power supply.
Replace the second power supply.
Replace the third power supply.
Replace the fourth power supply.
19
Diagnostics