Error Code/Symptom
188 (Bad EEPROM CRC #2)
189 (An attempt was made to
access the server with invalid
passwords)
201 (Memory test error, see
"Memory Settings" on page 34.)
If the server does not have the
latest level of BIOS installed,
update the BIOS to the latest
level and run the diagnostic
program again.
229 (Cache error)
289 (DIMM has been disabled
by user or system, see "Memory
Settings" on page 34.)
301 (Keyboard or keyboard
controller error)
303 (Keyboard controller error)
602 (Invalid diskette boot
record)
604 (Diskette drive error)
605 (Unlock error)
662 (Diskette drive
configuration error)
762 (Coprocessor configuration
error)
962 (Parallel port error)
FRU/Action
1. Run Configuration/Setup
2. I/O Legacy Board
1. Run Configuration/Setup, enter the administrator
password
2. I/O Legacy Board.
1. Run memory diagnostics.
2. DIMM
3. Memory card
4. Processor/PCI Board
5. I/O Legacy Board
1. Processor
2. Optional Processor (if installed)
3. Processor/PCI Board
1. Run Configuration/Setup, if disabled by user
2. Disabled DIMM, if not disabled by user.
3. Processor/PCI Board
1.
Keyboard
2. I/O Legacy Board
1. I/O Legacy Board
2. Keyboard
1. Diskette
2. Diskette Drive
3. Cable
4. I/O Legacy Board
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Legacy Board
1. Diskette drive
2. Drive cable
3. I/O Legacy board
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Legacy Board
1. Run Configuration/Setup utility
2. Battery
3. Processor
4. Processor/PCI board
1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. I/O Legacy Board
133
Symptom-to-FRU index