Disassembly Procedures
There are two basic types of cable connectors.
Pressure plate connector
Normal pin connector
To disconnect the cable from a pressure plate connector, lift the tab on either side of the
plastic pressure plate of the connector, and gently pull the cable out from the connector. To
connect the cable to a pressure plate connector, lift the pressure plate high enough and slide
the cable into the connector. Push the pressure place at both ends so the plate and connector
will be at the same height, then fasten the cable at the correct position. Hold the cable, gently
pull it, and make sure that the cable is securely in place. If the cable slips out of the
connector, make that the pressure plate is lifted high enough, and connect the cable again.
Standard pin connectors are used for all other cables. The cables can be connected to and
disconnected from these connectors by simply pulling or pushing.
Reassembly Procedures
To reassemble the computer after disassembling it and repairing the parts that caused its
malfunction, observe the general instructions given below.
Take time and reassemble it properly as instructed. Hasty work often raises problems.
Check that the cables and connectors are securely fastened.
Before mounting the FRUs and other parts, check that the cables are not caught by
screws or FRUs.
Check that all the latches are correctly closed.
Check that all FRUs have been fastened securely with all the screws. If the wrong
screws are used, it may result in damage to the screw threads and heads or the FRUs
may not be fixed securely.
After repairing, put all items which are removed from target machine.
After mounting the FRUs back in position, check that the computer operates normally.