Novell ZENWORKS HANDELD MANAGEMENT 7 SP1 IR4 - ADMINISTRATION Administration Manual page 65

Hide thumbs Also See for ZENWORKS HANDELD MANAGEMENT 7 SP1 IR4 - ADMINISTRATION:
Table of Contents

Advertisement

7 In the Path field in the Source Files box, specify the path to the source files.
8 In the Files field, browse to or specify the source files to be retrieved from the Windows CE
device.
You can use wildcard characters to specify source files.
When the policy is enforced, all specified source files are retrieved from the device; the files
are retrieved even if the same files were previously retrieved at another time.
9 Select the Files Are Required check box if you want ZENworks Handheld Management to
report a failed status if the specified files do not exist on the Windows CE device or if the
specified wildcard characters do not provide a match for files on the device.
NOTE: For more information about policy status, see
Information," on page
10 Select the Delete Files After Retrieval check box if you want the specified source files to be
deleted from the Windows CE device after they have been retrieved from the handheld device.
If you do not enable this option, the source files are copied to the specified location but also
remain on the Windows CE device.
11 In the Path field in the Destination Location box, browse to or specify the destination location
where you want the specified files copied to.
The renamed file can include variables. To include variables, click the Insert button, then click
the desired variable.
The following variables are available for use:
Variable
Description
device
The CN of the device. For example, in Dan
m130.Handhelds.NovellBangalore, the string would be Dan m130.
devicedn
The full DN of the device. For example, In Dan
m130.Handhelds.NovellWheaton, the string would be Dan
m130.Handhelds.NovellWheaton.
user
The username of the device. This is the value stored in the zfhUserName
attribute for the object in the directory. When this value is not configured on
the handheld device, it is set to <Undefined>.
date
The date the file was retrieved from the handheld device. This value is the
date only; the time that the file was retrieved is not included. For example, if
the file was retrieved on September 15, 2002 at 3:15 p.m., the string would
be 2002-09-15. The string is always in the format of yyyy-mm-dd.
time
The time the file was retrieved from the handheld device. This value is for
the time only; the date that the file was retrieved is not included. For
example, if a file was retrieved on September 15, 2002 at 3:20 p.m., the
string would be 15-20. The string is always in the format of hh-mm, with hh
representing the hour in 24-hour format.
guid
The GUID for the handheld device.
server
The name of the server that received the data. This is the Windows NT
name of the server.
76.
Section 2.6, "Viewing Policy Status
Using ZENworks Handheld Management Policies
65

Advertisement

Table of Contents
loading

Table of Contents