NOTE: If you want to connect your PPC 2000 device using SSL, you must keep in mind
the following points:
2d Click Next.
2e Specify information for your geographic location in the Country/Region, State/
Providence, and City/Locality text boxes, then click Next.
2f Specify information about your organization and organizational unit, then click Next.
2g Specify the location in which you want to save the certificate request, then click Next.
2h Click Finish, then click OK.
NOTE: To use NCS: In ConsoleOne, click Tools, click Issue Certificate, then follow the
prompts. When having the certificate signed (if given a choice), have it saved in Base64
format.
Handheld PCs running Windows CE 3.0 and Pocket PC 2000 devices do not support
certificates originating from NCS.
3 Have the certificate signed by a Certificate Signing Authority, such as Novell Certificate
Services (NCS) or VeriSign. To have the certificate signed by NCS, continue with
skip to
4 (Conditional) Perform the following steps to have the certificate self-signed by NCS :
4a Launch Consoleone
4b In the left pane, click Security.
4c In the right pane, double-click the Certificate Authority for the tree.
4d In the Properties dialog box that displays, click Certificates. Click Self Signed Certificate.
4e Click Validate. Ensure that the status in the Certificate Validation dialog box displays
Valid, then click OK.
4f Click Export, then click Next.
4g Select File in Base64 format then click Finish to save the exported certificate in a Base64
format.
5 To import a server certificate before using SSL:
5a In the Configure IP - ZENworks Handheld Management Access Point dialog box, click
Import Server Certificate.
5b Click Next.
5c Ensure that the Process the Pending Request and Install the Certificate option is enabled,
then click Next.
5d Browse to the location where you saved the certificate during
162 Novell ZENworks 7 Handheld Management Administration Guide
The server address is stored as the IP address because the Domain Name Resolution does
not work on PPC 2000 devices.
If the PPC 2000 device is connected using IP client through wireless, you must specify
the IP address of the ZENworks Handheld Management Access Point instead of the
common name when you create the Certificate Signing Request (CSR). This enables
the device to validate the Certificate server. But if the device cradle syncs, you can
use the common name by selecting the Use Desktop Sync settings option in the
ZENworks Console that is available on the device.
Step
5.
Step
4, else
Step
4g, then click Open.