Configuring the BIMS
Device to Access the
BIMS Center Periodically
within a Specified Period
[SW7750] bims sharekey simple 1122334455667788
# Configure the IP address of the BIMS. The default port 80 is used.
[SW7750] bims ip address 10.153.21.97
# Configure the interval for accessing the BIMS center.
[SW7750] bims interval 2880
Network requirements
The BIMS device will access the BIMS center at 12:10 on May 1, 2005. From then
on, it will access the BIMS center every two days until 23:50 on October 1, 2005.
The IP address and port number of the BIMS center are 10.153.21.97 and 80
respectively.
Configuration procedure
1 Configure the BIMS center
Refer to "Configuring the BIMS Device to Access the BIMS Center Periodically at
Startup" on page 800.
2 Configure the BIMS device
# Enter system view.
<SW7750> system-view
# Enable BIMS.
[SW7750] bims enable
bims is enable
# Assign the device a unique identifier ar18-20-907.
[SW7750] bims device-id ar18-20-907
# Configure the shared key used between the BIMS center and device.
[SW7750] bims sharekey simple 1122334455667788
# Configure the IP address of the BIMS. The default port 80 is used.
[SW7750] bims ip address 10.153.21.97
# Configure the device to access the BIMS center at 12:10 on May 1, 2005, and
from then on at two-day interval until October 1, 2005 23:50.
[SW7750] bims specify-time 12:10 2005/05/01 23:50 2005/10/01 period 2