Connecting to the PLC

1-6

Connecting to the PLC

1-6-1 Features of FinsGateway and CX-Server

Item
Serial communications modes
for serial connections
Network communications
through a serial connection
Direct network connection
Node address setting range
Other features
CX-Process Tool version 5.1 or earlier. Therefore they cannot be down-
loaded to the Loop Controller.
Isolated Ai4 Terminal (PH41U, Block Model 572), Isolated Ai4 Terminal
(AD04U, Block Model 573), Ai4 Terminal (ADG41, Block Model 581),
Segment Program 3 (Block Model 158)
Similarly, the following ITEMs can be used only when LCB01/05 version 3.5
or later, LCB03 version 3.5 or later, and CX-Process Tool version 5.2 or later
are used.
Search Area Specification Wait (ITEM189), Search Area Number
(ITEM194), and Reference Input Search Method (ITEM190) for Segment
Program 2 search area specification
For details on particular ITEMs, refer to the Function Block Reference Manu-
Note
al.
Either one of the following communications drivers can be selected to support
the connection with a PLC (Programmable Controller):
• FinsGateway
• CX-Server
Selection is also possible when CX-Process Tool is started from the Start Menu,
or when Start Only is selected from the I/O Table Window using CX-Program-
mer that was installed from the CX-One only.
When using the CX-Process Tool installed from the CX-One, the default setting
is to not display the dialog box for selecting the communications driver.
Note If Start with Setting Inherited is selected from the I/O Table Window using CX-
Programmer that was installed from the CX-One, CX-Server will be used auto-
matically as the communications driver.
The following table compares the special features of the communications driv-
ers.
FinsGateway
Host Link (SYSWAY-CV) or peripheral bus
(toolbus)
Supported
Supported
1 or higher (cannot be set to 0)
• The same COM port can be used for si-
multaneous online connections with ap-
plications using FinsGateway (such as
PLC Reporter and SYSMAC OPC Serv-
er).
Note The PLC's node address must be set to 0 when using CX-Server and connecting
directly to the PLC in a 1:1 or 1:N connection. (The 1:N connection is possible
with Host Link communications only.) On the other hand, the node address can-
not be set to 0 when connecting to the PLC through FinsGateway; the node ad-
dress must be 1 or higher.
If CX-Server was selected as the communications driver and a Function Block
File (.ist) was created for node address 0 with filename "Node00" in that project,
the project (multi-node file) cannot be opened if FinsGateway is selected later.
Communications driver
Host Link or Peripheral Bus
Supported
Supported
Must be set to 0 when the computer is
connected directly to the PLC
• The same COM port can be used for si-
multaneous online connections with Tools
such as CX-Programmer, CX-Protocol,
and CX-Motion.
Section
1-6
CX-Server
31