Data Memory (DM) Allocation
Segment
Access
information
1: Temperature
Read
Controller
Write
2: Digital Panel
Read
Meter
Write
Starting Address of Read Data Area or Read Variable Type Area (Offset: +8, +11, ... , +98, and +101)
Setting
Starting Address
0000 to 9999 BCD
of Read Data Area
(DM address)
(SYSWAY proto-
col)
Starting Address
0000 to 9999 BCD
of Read Variable
(DM address)
Type Area
(CompoWay/
F protocol)
242
The following table shows the data that will be read and written for each com-
bination of the command group and segment information settings.
Data
Present temperature
Status
Target temperature
Alarm 1 SV
Alarm 2 SV
Proportional band
Reset time
Derivative time
Heater current
Heater current status
Target temperature
Operation command
Alarm 1 SV
Alarm 2 SV
Proportional band
Reset time
Derivative time
Heater burnout detection value
Display value
Display value status
Peak hold
Peak hold status
Bottom hold
Bottom hold status
Comparison value (HH)
Comparison value (H)
Comparison value (L)
Comparison value (LL)
Operation command
Comparison value (HH)
Comparison value (H)
Comparison value (L)
Comparison value (LL)
Use the following equation to calculate the offset for a given unit number:
Offset = 8 + (3 × unit number)
Range
Specifies the starting DM address in the CPU Unit's DM area where the data
read from the component will be stored.
A syntax error will occur if the starting address specified in this word is not BCD.
Specifies the starting DM address of the words that show which variables will be
read from the component.
The data that will be read from the component is determined by the variable
type and address written in the variable type area.
A syntax error will occur if the starting address specified in this word is not BCD.
Command group
1
2
YES
YES
YES
YES
YES
YES
YES
YES
YES
---
---
YES
---
---
YES
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
YES
YES
YES
---
YES
YES
---
---
YES
---
---
YES
---
---
---
---
---
---
---
---
---
---
---
---
YES
YES
YES
YES
YES
YES
---
YES
YES
---
YES
YES
---
YES
YES
---
YES
YES
---
---
---
---
---
---
---
---
---
---
---
---
---
---
YES
---
---
---
---
---
---
---
---
---
---
---
---
Function
Section 7-4
3
4
5
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
---
YES
---
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
---
YES
YES
YES
YES
YES
---
YES
---
YES
---
YES
---
YES
YES
YES
YES
YES
YES
YES
YES
YES
---
YES
YES
YES
YES
YES
YES
YES
YES
YES

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cpm2c

Table of Contents