7. Monitoring and Troubleshooting

Entry Response Messages

The messages in
to commands or during data entry. They appear in the messages area at the
bottom of the ATI screen and are listed in alphabetical order.
Table 7-4.
7-8
Table 7-4, Entry Response
Entry Response Messages (1 of 2)
Device Message
What Message Indicates
0.0.0.0 is an invalid
An IP address of all zeros
IP address
was entered.
Access level is
The operator requested that
Operator.
configuration options be
Configuration is
loaded, but does not have
read-only.
authority to edit them.
Cannot Save – no
All of the login IDs being
Login IDs with Access
saved have an access level
Administrator
below Administrator.
Command Complete
Action requested has
successfully completed.
Invalid Character
A nonprintable ASCII
character has been entered.
Invalid – Data Terminal
Network-initiated loopback
Initiated Loopback
was in progress when the
Active
selection was made.
Invalid entry at cursor
Invalid IP address for this
function.
Invalid Password
Login is required and an
incorrect password or Login
ID was entered; access is
denied.
Invalid – [Test] Already
The described test was
Active
already in progress when the
selection was made.
Invalid Test
A loopback or pattern test
Combination
was in progress when Start
was selected to start the test,
or was active on the same
interface when the test was
selected.
December 2001
Messages, can appear in response
What To Do
Enter a valid, non-zero
IP address.
If configuration options are to be
edited, use a Login ID that has
Administrator authority.
Change the access level of
at least one Login ID to
Administrator so that
configuration changes can be
made. (Operator-level users
cannot make configuration
changes.) Save the Login IDs.
No action is needed.
Reenter the information using
valid characters.
No action is needed.
Enter a valid IP address. See the
appropriate table in
Appendix A,
Configuration Options
determine the permitted address
range for this field.
T
Enter the correct Login ID
and password combination.
T
Contact your system
administrator to verify your
Login ID and password.
T
Allow the test to continue.
T
Select another test.
T
Stop the test.
T
Wait unit the other test ends.
T
Abort all tests from the Test
menu screen.
T
Stop the test from the same
screen from which the test
was started.
7900-A2-GB21-20