Appendix
A.1 New and extended functions
A.1.7
Firmware version 4.7
Table A-7
New functions and function changes in Firmware 4.7
Function
1
Supporting the identification & maintenance datasets (I&M1 ... 4)
2
Fall in pulse rate with increased drive power required by the motor
•
The converter temporarily lowers the pulse frequency if required when the
motor is started up, and simultaneously increases the current limit.
3
S7 communication
•
Direct data exchange between the converter and human-machine interface
(HMI).
•
Increase in communication performance with the engineering tools and sup‐
port of the S7 routing
4
The basic functions of Safety Integrated are unrestrictedly available in all control
types with 1FK7 encoderless permanent-field synchronous motors
5
Encoderless 1FK7 synchronous motors are supported
•
Direct motor selection based on the article number with associated code
number
•
It is not necessary to input individual motor data
6
Pulse input as source of setpoint value
•
The converter calculates its speed setpoint from a sequence of pulses at the
digital input.
7
Dynamic IP address assignment (DHCP) and temporary device names for PROFI‐
NET
8
PROFIenergy device profile 2 and 3
9
Uniform behavior for component replacement
•
After a component is replaced, a converter with activated Safety Integrated
will report what type of component has been replaced using a unique code.
10
Improved direct-component control in PM230
•
Optimized efficiency for pump and fan applications
11
Rounding down of BACnet and macros
458
✓
✓
✓
-
-
-
✓
✓
✓
-
-