5
Solenoid Hold-in Test
See
Figure 5-10.
With test leads still connected in the manner
specified in the previous
nect solenoid "C" terminal/battery negative test lead at
battery negative end only; reconnect loose end of this
test lead to battery positive, instead. If pinion remains in
pull-in position, solenoid is working properly. If pinion does
not remain in pull-in position, solenoid should be replaced.
b0162x5x
"C" terminal
Figure 5-10. Hold-In Test
Solenoid Return Test
See
Figure 5-11.
With test leads still connected in the manner
specified at the end of the previous
TEST, disconnect solenoid "50" terminal/battery positive
test lead at either end. If pinion returns to its original posi-
tion, the solenoid is working properly. If pinion does not return
to its original position, solenoid should be replaced.
b0163x5x
"C" terminal
Figure 5-11. Return Test
5-12
SOLENOID PULL-IN
TEST, discon-
"50" terminal
Battery
SOLENOID HOLD-IN
"50" terminal
Battery
www.PlanDeGraissage.org
DISASSEMBLY, INSPECTION
AND REPAIR
Remove field wire (22).
1.
See
Figure 5-14.
2.
See
Figure 5-12.
Remove thru-bolts.
4860
Figure 5-12. Removing the Thru-Bolts
3.
See
Figure 5-13.
Remove two end cover screws, O-rings,
and end cover.
3548a
End cover
Figure 5-13. Removing End Cover
Thru-bolts
End cover
screws (2)