2-6 DS3 tests, STS-1 tests, and optical in-bay tests
Procedure 2-1
Verifying STS-1 tributary SONET test set performance
Use this procedure to verify STS-1 SONET test set performance. This
verification is necessary to obtain reliable results when performing tests on a
system equipped with STS-1 tributaries.
This procedure describes settings for HP test sets. Other brands of test sets use
similar settings.
Requirements
You need the following tools and materials:
•
•
Action
Step
SONET test set
1
2
3
AccessNode Vol 3B 323-3001-221 Issue 2.0
one (1) HP 37704A SONET test set or equivalent
one (1) electrical test cord
Action
Set the Power switch to ON.
Set the Transmit Out settings as follows:
Transmit signal:
Clock sync:
STS SPE under test: 1
Set the Error Inject controls as follows:
Type:
Error Rate:
STS-1
Internal or External BITS (as appropriate)
Line CV
OFF