14.8.10 GAS_ID13: Flame fault during operation
14.9 Testing the gas components
14.9.1 Checking the electrodes
a
X1
Neutral/Line
10
6
5
1
110V
110V
Preparations •
INFORMATION
Troubleshooting
Description
The error message appears sporadically or continuously.
Troubleshooting
If the error occurs again, replace the ignition electronics. If the error
persists, contact the manufacturer.
b
3 µA
F1 3,15A
a Ignition electronics A10 / A20
b Transformer T10 / T20
Glow electrode
On the Service menu, select the Gas CO
Only begin troubleshooting when Gas request lights up green.
•
The transformer (b) is only supplied with voltage with active gas request. The
glow electrode can be checked visually through the sight glass on the gas
burner.
Check output voltage on the transformer.
The voltage is 24 V.
Check the current consumption of the glow electrode. This must
be at least 1.4 A.
Service instructions
Fault messages & troubleshooting
c
24-28V, ~1,4A
c Ionization electrode (flame
monitoring) B100 / B200
d Glow electrode F10 / F20
calibration and start.
2
d
119