Figure 276. Loosening the pivot screw
5. Align the insert the GPU cold plate along with handle in the GPU socket. Using the Torx 15 screwdriver, tighten the screws
with 4 in-lbf torque value to secure the screws on the GPU cold plate. The sequence to tighten the screws is 1, 2, 3 and 4 as
mentioned on the handle. Use the same sequence to fully tighten the 4 screws with 4 in-lbf torque value on the cold plate.
Pull the plunger and lift the metallic piece. Plug the cold plate tubes in to the Manifold Liquid cooling. Close the metallic piece
and release the plunger to click into its place.
Figure 277. Removing the GPU cold plate with handle
6. Using the Torx 15 screwdriver, loosen the screw of the handle and lift the handle away from the GPU cold plate.
Installing and removing system components