114
To set the operating pressure:
1.
Pull the pressure controller (1) up.
2.
Turn the pressure controller until the pressure gage (2) indi-
cates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure controller (1) down.
6.3.2

Draining the water condensation

NOTICE
Property damage from excess water!
Excess water can cause damage to the machine.
Drain water as required.
Water condensation accumulates in the water separator (2) of the
pressure controller.
Proper setting
Water condensation must not rise up to the level of the filter
element (1).
Check the water level in the water separator (2) on a daily basis.