Code
Possible cause
1008
Encoder error
1010
External synchronizer
plug (Sub-D, 9-pin) not
connected
1011
Encoder Z pulse
missing
1012
Synchronizer fault
1054
Internal short circuit
1055
Sewing motor
overload
1060
Sewing motor
overload/excess
voltage/excess
current/
1061
Sewing motor
overload/excess
voltage/excess
current/
1120
Sewing motor Init fault • Perform software update
1121
Sewing motor
watchdog
Remedial action
• Replace the encoder
• Connect cable of external
synchronizer to control, use correct
connection (Sync)
• Only required for machines with
transmission!
• Switch off the control, use
handwheel to turn, and switch on
the control again
• If error is not corrected, check
encoder
• Replace the synchronizer
• Replace the control
• Eliminate stiff movement in the
sewing machine
• Replace the encoder
• Replace sewing motor
• Check class
• Replace the control
• Replace the encoder
• Replace sewing motor
• Check class
• Replace the control
• Replace the encoder
• Replace sewing motor
• Check class
• Perform software update
• Check class