Code
Possible cause
2222
DA stepper card Y
flywheel position not
found
2230
DA stepper card Y not
responding
2231
DA stepper card Y Init
fault
2252
DA stepper card
excess current
2271
DA stepper card Y
watchdog (sewing foot
lift)
2301
DA stepper card Z
reference run timeout
(sewing foot stroke)
2305
DA stepper card Z
motor blocked
2321
DA stepper card Z
encoder plug (Sub-D,
9-pin) not connected
2322
DA stepper card Z
flywheel position not
found
2330
DA stepper card Z not
responding
2331
DA stepper card Z Init
fault
2352
DA stepper card Z
excess current
Remedial action
• Check stepper motor 1 for stiff
movement
• Perform software update
• Replace the control
• Perform software update
• Check class
• Check for stiff movement
• Perform software update
• Check class
• Check reference sensor
• Check for stiff movement
• Insert the plug into the control, use
correct connection
• Check stepper motor 1 for stiff
movement
• Perform software update
• Replace the control
• Perform software update
• Check class
• Check for stiff movement