3.7 Stitch Condensation

22
The stitch condensation is set with the step cylinder. It must be
activated at the controls via function F3.
The carrier 1 sets the stitch regulator guide 4 for the main feed dog at
the correct stitch length by stitch condensation.
Caution Risk of Injury !
Turn off main switch before adjusting.
At the controls set the value for crimping at 0.
Loosen screw 2.
Set carrier 1 tight with pin 3.
Tighten screw 2.
1
2
3
4