H2: Digital Outputs - YASKAWA GA80U4720ABM Manual

Table of Contents

Advertisement

Setting Value
Function
7B
KEB Ride-Thru 2
Activate (N.O.)
7C
Short Circuit Braking (N.
O.)
7D
Short Circuit Braking (N.
C.)
7E
Reverse Rotation
Identifier
90 - 97
DWEZ Digital Inputs 1 to
8
9F
DWEZ Disable
101 to 19F
Inverse Inputs of 1 to 9F

H2: Digital Outputs

No.
Name
(Hex.)
H2-01
Term M1-M2 Function
Selection
(040B)
H2-02
Term M3-M4 Function
Selection
(040C)
H2-03
Term M5-M6 Function
Selection
(040D)
H2-06
Watt Hour Output Unit
Selection
(0437)
YASKAWA SIEPC71061737B GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.O.).
ON : Short Circuit Braking is enabled.
OFF : Normal operation
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.C.).
ON : Normal operation
OFF : Short Circuit Braking is enabled.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rotation direction of the motor when in Simple Closed Loop V/f Control method and F1-21, F1-37 = 0
[Encoder Option Function Selection = A pulse detection], or when in Closed Loop V/f Control method.
ON : Reverse run
OFF : Forward run
V/f
CL-V/f
OLV
CLV
AOLV
Sets digital inputs used with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the DriveWorksEZ program saved in the drive.
ON : No
OFF : Yes
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Digital input] to enable this function.
Sets the function of the selected MFDI to operate inversely. To select the function, enter "1xx", where the "xx" is the
function setting value.
Note:
You cannot use inverse input for all functions. Refer to
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M1-M2.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in
through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M3-M4.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in
through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M5-M6.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in
through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the unit for the output signal when H2-01 to H2-03 = 39 [MFDO Function Selection
= Watt Hour Pulse Output].
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Table 12.55
for more information.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.10 H: Terminal Functions
Ref.
844
845
845
845
845
845
846
Default
Ref.
(Range)
0
848
(0 - 1FF)
1
848
(0 - 1FF)
2
848
(0 - 1FF)
0
849
(0 - 4)
11
531

Advertisement