Inverse Inputs of 0 to FF Sets the function of the selected MFDI to operate inversely. To select the function, enter "1xx", where "xx" is the

H2: Digital Outputs

No.
Name
(Hex.)
H2-01
Term M1-M2 Function
Selection
(040B)
H2-02
Term M3-M4 Function
Selection
(040C)
H2-03
Term M5-M6 Function
Selection
(040D)
H2-04
Term P1-C1 Function
Selection
(040E)
H2-05
Term P2-C2 Function
Selection
(040F)
H2-06
Watt Hour Output Unit
Selection
(0437)
H2-07
Modbus Register 1
Address Select
(0B3A)
H2-08
Modbus Register 1 Bit
Select
(0B3B)
H2-09
Modbus Register 2
Address Select
(0B3C)
H2-10
Modbus Register 2 Bit
Select
(0B3D)
H2-20
Comparator 1 Monitor
Selection
(1540)
H2-21
Comparator 1 Lower
Limit
(1541)
H2-22
Comparator 1 Upper
Limit
(1542)
H2-23
Comparator 1 Hysteresis
(1543)
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Set the function for the drive to self-test RS-485 serial communications operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to hold a stopped motor.
function setting value.
Note:
You cannot use inverse input for all functions. Refer to
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M1-M2.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M3-M4.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M5-M6.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal P1-C1.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal P2-C2.
Note:
When you do not use the terminal or when you use the terminal in through mode,
set this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the unit for the output signal when H2-01 to H2-05 = 39 [MFDO Function
Selection = Watt Hour Pulse Output].
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
V/f
CL-V/f
OLV
CLV
AOLV
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor number for comparator 1. Set the x-xx part of the Ux-xx [Monitor]. For
example, set H2-20 = 102 to monitor U1-02 [Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the lower limit detection level for comparator 1 when the full scale analog output
for the monitor selected in H2-20 [Comparator 1 Monitor Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit detection level for comparator 1 when the full scale analog output
for the monitor selected in H2-20 [Comparator 1 Monitor Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the hysteresis level for comparator 1 as a percentage of the full scale analog output
for the monitor selected in H2-20 [Comparator 1 Monitor Selection].
10.10 H: Terminal Functions
Description
Table 11.26
for more information.
Ref.
701
701
701
Default
Ref.
(Range)
21
704
(0 - 1FF)
0
704
(0 - 1FF)
2
704
(0 - 1FF)
6
704
(0 - 1FF)
10
704
(0 - 1FF)
0
704
(0 - 4)
0001
705
(0001 - 1FFF)
0000
705
(0000 - FFFF)
0001
705
(0001 - 1FFF)
0000
705
(0000 - FFFF)
102
706
(000 - 999)
0.0%
706
(0.0 - 300.0%)
0.0%
706
(0.0 - 300.0%)
0.0%
706
(0.0 - 10.0%)
503