Set Input Signals For Mfai Terminals A1 To A3 - YASKAWA GA80U4720ABM Manual

Table of Contents

Advertisement

A - Load Impedance
• Use in sinking mode
The external power supply changes the voltage level of the pulse train output signal. Keep the voltage from an
external source between 10.8 Vdc to 16.5 Vdc. Adjust the load impedance to keep the current at 16 mA or lower.
External Power Supply (V)
10.8 Vdc to 16.5 Vdc
A - External power supply
B - Load Impedance

Set Input Signals for MFAI Terminals A1 to A3

Use terminals A1 to A3 to input a voltage or a current signal. Set the signal type as shown in
DIP Switch Settings
Terminal
Input Signal
Switch
Voltage input
A1
S1-1
Current input
Voltage input
A2
S1-2
Current input
YASKAWA SIEPC71061737B GA800 Drive Technical Reference
Figure 3.47 Wiring to Use Pulse Train Output in Sourcing Mode
Load Impedance (kΩ)
Figure 3.48 Wiring to Use Pulse Train Output in Sinking Mode
Figure 3.49 Location of DIP Switch S1
Table 3.15 MFAI Terminals A1 to A3 Signal Settings
Setting
No.
V
0: 0 V to 10 V/0% to 100% (input impedance: 20 kΩ)
(Default)
1: -10 V to +10 V/-100% to 100% (input impedance: 20 kΩ)
H3-01
2: 4 mA to 20 mA/0% to 100% (input impedance: 250 Ω)
I
3: 0 mA to 20 mA/0% to 100% (input impedance: 250 Ω)
0: 0 V to 10 V/0% to 100% (input impedance: 20 kΩ)
V
1: -10 V to +10 V/-100% to 100% (input impedance: 20 kΩ)
H3-09
I
2: 4 mA to 20 mA/0% to 100% (input impedance: 250 Ω)
(Default)
3: 0 mA to 20 mA/0% to 100% (input impedance: 250 Ω)
1.0 kΩ or more
C - Sinking current
Parameter
Signal Level
3.6 Control I/O Connections
Sinking current (mA)
16 mA maximum
Table
3.15.