Added Digital Outputs; Added Faults And Alarms; Fast Stop - Edge Triggered; Related Parameters And Monitors - YASKAWA L1000A CIMR-LC F Series Technical Manual Addendum

Ac drive for lift applications
Table of Contents

Advertisement

Added Digital Outputs

H2-xx Setting (Hex)
75 (175)
76 (176)
77 (177)

Added Faults and Alarms

Added Faults
Fault Code
Fault
Fault
(Hex)
Display
TDCC Fault
6B
TCF
TDCC
EEPROM
6C
TCE
Memory Data
Error
Added Alarms
Fault Code
Fault
Fault
(Hex)
Display
TDCC Alarm
4D
TCA
TDCC Setup
4E
TCS
13

Fast Stop - Edge Triggered

Related Parameters and Monitors

Added Digital Inputs

H1-xx Setting (Hex)
5E (15E)
YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum
Operator Display
TDCC Pulse Output
TDCC Pulse Outp
With every increment of the TDCC, a pulse of 0.5 s pulse width is output.
TDCC Alarm Level Reached
TDCC AlmLvl Rch
Indicates that the TDCC alarm level is reached.
TDCC Fault Level Reached
TDCC FltLvl Rchd
Indicates that the TDCC has reached 0 value.
Description
TDCC Fault
Elevator ropes need to be replaced.
TDCC EEPROM Memory Data Error
Error, while reading the EEPROM section
related to TDCC, while powering on.
Description
TDCC Alarm
Elevator ropes need to be replaced soon.
Set o4-40 = 0 to disable the alarm.
TDCC Setup
The TDCC function needs to be set up.
Set o4-40 = 0 to disable the alarm. TCS
has higher priority than TCA.
Operator Display
Emergency Stop 2 (N.O.)
Deactivation slope: Decelerates with Emergency Stop Time [C1-09] triggered by falling edge.
Fast-Stop 2 N.O.
Even if the Emergency Stop command is cleared, the drive will not operate without cycling the Run
command.
Figure 13.1 Emergency Stop Sequence Fast Stop 2 (N.O.)
13 Fast Stop - Edge Triggered
Description
Cause
Elevator rope lifetime exceeded (TDCC
Counter = 0)
EEPROM might be broken
Cause
The TDCC value fell below the alarm
threshold [TDCC < o4-41].
o4-40 is active although no password is
set to activate the function.
Description
Countermeasure
Change ropes. Enter password in o4-44
and set o4-40 = 2 to initialize the counter.
This resets the counter to the value of o4-
42.
Power off and wait for the drive's DC bus
to discharge. Power on if the "charge"
LED is off. If the problem occurs again,
replace the control board or the whole
drive.
Countermeasure
Replace the ropes soon.
Set up TDCC function.
87
EN