H2: Digital Outputs - YASKAWA CIPR-CR70A Series Technical Manual

Ac drive for cranes 200/400 v class: 0.4 to 110/315 kw
Table of Contents

Advertisement

Setting
Function
38
Counterweight
Selection
39
Motor 3 Selection
3A
Micro Speed Gain1
3B
Micro Speed Gain2
40
Forward RUN (2-
Wire)
41
Reverse RUN (2-
Wire)
44
Add Offset
Frequency 1 (d7-
01)
45
Add Offset
Frequency 2 (d7-
02)
46
Add Offset
Frequency 3 (d7-
03)
47
Node Setup
(CANopen)
60
DC Injection
Braking Command When the DC Injection Braking command is input while the drive is in stopping
67
Communications
Test Mode
72
Zero Servo
100 to 1FF Inverse Input of 0
to FF

H2: Digital Outputs

No.
Name
(Hex.)
H2-01
Term M1-M2
Function Selection Selects the function assigned to MFDO terminal M1-M2.
(040B)
H2-02
Term M3-M4
Function Selection Selects the function assigned to MFDO terminal M3-M4.
(040C)
H2-03
Term M5-M6
Function Selection Sets the function for MFDO terminal M5-M6.
(040D)
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Switch C4-02 [Torque Compensation Delay Time], E1-08 [Mid Point A Voltage] and E1-
10 [Minimum Output Voltage]. Enabled parameters are decided based on the combination
of the condition of the terminals ON or OFF and Run command orientation (Forward/
Reverse).
V/f
CL-V/f
OLV
CLV
AOLV
Switches motor 1 or motor 2 to motor 3. Switch between motors when they are stopped.
ON : Selects motor 3
OFF : Select motor 1 or motor 2 (Select the terminal assigned H1-xx = 16 [Motor 2
Selection])
V/f
CL-V/f
OLV
CLV
AOLV
Multiplies the gain set in S2-16 [Micro Speed Gain1] by the final step of frequency
reference when the terminal is on.
V/f
CL-V/f
OLV
CLV
AOLV
Multiplies the gain set in S2-17 [Micro Speed Gain2] by the final step of frequency
reference when the terminal is on.
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the Forward run command for 2-wire sequence 1. Use it paired with the Reverse
RUN (2-Wire) [H1-xx = 41].
ON : Forward Run
OFF : Run Stop
V/f
CL-V/f
OLV
CLV
AOLV
Inputs the Reverse run command for 2-wire sequence 1. Use it paired with the Forward
RUN (2-Wire) [H1-xx = 40].
ON : Reverse Run
OFF : Run Stop
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-01 [Offset Frequency 1] to the
frequency reference when the terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-02 [Offset Frequency 2] to the
frequency reference when the terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-03 [Offset Frequency 3] to the
frequency reference when the terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function in CANopen communications to start the Node Setup function to set the
drive node address from the host controller.
V/f
CL-V/f
OLV
CLV
AOLV
operation, DC Injection Braking is applied to stop the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Set the function for the drive to self-test RS-485 serial communications operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to hold a stopped motor.
Performs inverse input on the function of the selected MFDI. Sets the function for which
to generate inverse input by specifying the last 2 digits of 1xx (00 to FF).
Description
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Description
10 Parameter List
Ref.
657
197
203
658
193
203
658
193
203
658
193
203
658
658
658
659
659
659
659
659
659
659
Default
Ref.
(Range)
21
662
(0 - 1FF)
0
662
(0 - 1FF)
2
662
(0 - 1FF)
461