H2: Digital Outputs - YASKAWA GA700 Technical Manual

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.10 H: Terminal Functions
Setting
Function
7D
Short Circuit
Braking (N.C.)
7E
Reverse Rotation
Identifier
7F
PID Bi-Directional
Enable
90 to 97
DriveWorksEZ
Digital Inputs 1 to
8
9F
DWEZ Disable
101 to 19F Inverse Input of 1
to 9F

H2: Digital Outputs

No.
Name
(Hex.)
H2-01
Term M1-M2
Function Selection Sets the function for MFDO terminal M1-M2.
(040B)
H2-02
Term M3-M4
Function Selection Sets the function for MFDO terminal M3-M4.
(040C)
H2-03
Term M5-M6
Function Selection Sets the function for MFDO terminal M5-M6.
(040D)
552
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.C.).
ON : Normal operation
OFF : Short Circuit Braking is enabled.
Note:
When A1-02 = 8 [Control Method Selection = EZ Open Loop Vector Control], this
function is available if you use a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rotation direction of the motor when in Simple Closed Loop V/f Control method
and F1-21, F1-37 = 0 [Encoder Option Function Selection = A pulse detection], or when
in Closed Loop V/f Control method.
ON : Reverse
OFF : Forward
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the PID Bi-Directional function.
ON : Enabled
OFF : Disabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets digital inputs used with DriveWorksEZ. Refer to the DriveWorksEZ Online Manual
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the DriveWorksEZ program saved in the drive.
ON : Disabled
OFF : Enabled
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Digital input] to use this
function.
Sets the function of the selected MFDI to operate inversely. To select the function, enter
"1xx", where the "xx" is the function setting value.
Note:
You cannot use inverse input for all functions. Refer to
information.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Note:
Set this parameter to F when the terminal is not being used or to
use the terminal in through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Note:
Set this parameter to F when the terminal is not being used or to
use the terminal in through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Note:
Set this parameter to F when the terminal is not being used or to
use the terminal in through mode.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Table 11.59
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Ref.
885
886
886
886
886
886
for more
Default
Ref.
(Range)
0
889
(0 - 1A7)
1
889
(0 - 1A7)
2
889
(0 - 1A7)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents