H2: Digital Outputs - YASKAWA LA500 Technical Manual

Ac micro drive
Table of Contents

Advertisement

11.8 H: Terminal Functions
Setting Value
Function
41
Reverse RUN (2-Wire)
50
Nominal Speed
51
Intermed Speed
52
Releveling Speed
53
Leveling Speed
54
Inspection Speed
55
Rescue Operation
56
Motor Contractor
Feedback
79
Brake Feedback

H2: Digital Outputs

No.
Name
(Hex.)
H2-01
Term MA/MB-MC
Function Selection
(040B)
H2-02
Term P1-C1 Function
Selection
(040C)
H2-03
Term P2-C2 Function
Selection
(040D)
250
V/f
OLV
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 40 [Forward RUN (2-Wire)]
together.
ON : Reverse Run
OFF : Stop
Note:
• If you turn ON the Forward Run command terminal and the Reverse Run command terminal, it will cause an
EF [FWD/REV Run Command Input Error] alarm and the motor will ramp to stop.
• Initialize the drive with a 2-wire sequence to set the Reverse Run command to terminal S2.
• This function will not operate at the same time as H1-xx = 42, 43 [Run Command (2-Wire Sequence 2),
FWD/REV (2-Wire Sequence 2)].
V/f
OLV
Sets the speed reference nominal speed.
V/f
OLV
Sets the speed reference intermediate speed 1. In combination with nominal and releveling speed you can set
intermediate speed 2 and 3.
V/f
OLV
Sets the speed reference releveling speed.
V/f
OLV
Sets the speed reference leveling speed.
V/f
OLV
Sets the speed reference inspection speed.
V/f
OLV
Activates rescue operation.
V/f
OLV
Used for motor contactor supervision and fault detection.
V/f
OLV
Used for brake supervision and detection of incorrect operation.
Description
V/f
OLV
Sets the function set for MFDO terminal MA-MC or MB-MC.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in
through mode.
V/f
OLV
Sets the function for MFDO terminal P1-C1.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in
through mode.
V/f
OLV
Sets the function for MFDO terminal P2-C2.
Note:
Set this parameter to F when the terminal is not being used or to use the terminal in
through mode.
Description
YASKAWA SIEPYEULA5001C LA500 Technical Manual
Ref.
309
309
309
309
309
309
309
310
310
Default
Ref.
(Range)
E
311
(0 - 158)
6
311
(0 - 158)
50
311
(0 - 158)