Table 6-2 RCM Status Command Fields
Item
Firmware Rev:
Escape Sequence:
Remote Access:
Alerts:
Alert Pending:
Temp (C):
RCM Power Control:
RCM Halt:
External Power:
Server Power:
Description
Revision of RCM firmware.
Current escape sequence to invoke RCM.
Modem remote access state. (ENABLE/DISABLE)
Alert dial-out state. (ENABLE/DISABLE)
Alert condition triggered. (YES/NO)
Current system temperature in degrees Celsius.
Current state of RCM system power control. (ON/OFF)
Asserted indicates that halt has been asserted with the
haltin command. Deasserted indicates that halt has
been deasserted with the haltout command or by
cycling power with the On/Off button on the control
panel. The RCM Halt: field does not report halts
caused by pressing the Halt button.
Current state of power to RCM. Always on.
Indicates whether power to the system is on or off.