Example 4-8 Show Power Command
P00>>> show power
Power Supply 0
Power Supply 1
System Fans
CPU Fans
Temperature
Current ambient temperature is 23 degrees C
System shutdown temperature is set to 55 degrees C
The system was last reset via a system software reset
0 Environmental events are logged in nvram
Do you want to view the events? (Y/<N>) y
Total Environmental Events: 5 (5 logged)
1
JUL 25
1:17
2
Jul 29 23:44
3
Jul 29 23:51
4
Jul 30
0:18
5
Jul 30 19:22
Do you want to clear all events from nvram? (Y/<N>) y
P00>>>
The show power command displays status information about the power supplies,
system fans, CPU fans, and temperature. This command is useful for displaying the
error state of a DIGITAL UNIX or OpenVMS system that shuts down because of a
fan, temperature, or power supply failure. If the system can be restarted, use this
command. (If it cannot, use the RCM status command. See Chapter 6.)
The syntax is:
show power
4-14
User's Guide
Status
good
good
good
good
good
Temperature, Fans, Power Supplies Normal
Temperature, Fans, Power Supplies Normal
Temperature, Fans, Power Supplies Normal
System Fan 0 Failure
Temperature, Fans, Power Supplies Normal

Advertisement