Configure PoE -- System

poe limit-mode
Description:
Configure System PoE power limit mode information
Command Level
Global Configuration
Syntax:
poe limit-mode { Consumption / Classification / Total-Limit }
Parameters:
<Consumption> Power is allocated according to the actual need of each PD.
<Classification> The system will handle power allocation according to class (0 to 4)
<Total Limit> Set limit value of the total POE port provided power to the PDs
Example:
Switch(config)# poe limit-mode Consumption
Switch (config)# show poe
Maximum Available Power
System Operation Status
POE Admin mode
Temperature Unit1
Temperature Unit2
Over Temperature
PoE Power Consumption
Temperature Threshold
Usage
Usage Threshold
PoE Power limit mode
poe admin-mode
Description:
Configure System PoE Admin mode information
Command Level
Global Configuration
Syntax:
poe admin-mode { enable / disable }
[no] poe admin-mode
Parameters:
<enable > Enable POE
<disable > Disable POE.
PoE admin-mode command has included in NS2503-8P/2C only.
Example:
Switch(config)# poe admin-mode enable