C. Connect Extension Cable (36 pin) between P3503 on the Main
C.B.A. and LCD Blue Unit.
5. Carefully place the Main C.B.A. as shown in Fig. 3-1-2.
Note:
The LCD Projector power cannot be turned on unless the Air Filter unit is correctly installed.
6. After servicing, remove Extension Cables.
7. Reinstall the Main C.B.A., and reconnect connectors.
8. Make sure that all wires and leads are placed in their original
position.
3.2. How to display Lamp operation time (Service Mode)
1. Connect a jumper wire between TP6012 and TP6013 on Main
C.B.A. for over 5 seconds as shown in Fig. 3-2-1.
PDF created with pdfFactory Pro trial version
Fig. 3-1-2
Fig. 3-2-1