Symptom of Misadjustment:
LCD panel may be damaged.
Note:
TP1904, TP1907, TP1908: MAIN C.B.A.
1. Connect the DVM (Digital Volt Meter) to TP1904 or TP1908.
2. Press
or
button on the remote control to select"15.3V".
3. Press
or
button so that the voltage shown in the display of
DVM is 15.3 V± 0.05 V DC.
5.4.14. RGB INPUT LEVEL ADJUSTMENT
Purpose:
To set the optimum signal level.
Symptom of Misadjustment:
The picture will be too light or too dark.
Note:
TP3501, TP3502, TP3503: Main C.B.A.
1. Supply Gray Scale Pattern Signal (3 scales).
2. Connect the oscilloscope to TP3501.