Fig No.
P3501
P3502
P3503
P6005
(Removal and Installation of Flexible Cable )
- Removal
1. On the Trap Connector, swing both ends of the Locking Tab to
release the Trap portion of the Connector. Then pull Flexible
Cable out to remove as shown in Fig. 3-6-1.
- Installation
1. Insert the end of the Flexible Cable into the Trap Connector.
2. Without twisting the Cable, press the Locking Tab in into its
locked positions.
3. Gently and slightly pull up on the Cable to confirm if it is installed
firmly.
3.7. Wire and Lead Position Diagram
After servicing, make sure that all wires and leads are placed in their original position.It is
important for the best operation of the unit.