Verifying a successful configuration
Testing the Leader Signaling Server
Communication Server 1000M and Meridian 1
To ensure that the Signaling Server Ethernet connections (for the ELAN and
TLAN subnets) are configured correctly, perform a ping test to one or more
of the other devices connected to the network, particularly the Call Server.
Procedure 64
Verifying the Signaling Server Ethernet connection
1
Log in to the Signaling Server, using Procedure 63 on
2
Ping the IP address of the Signaling Server. Enter the command:
ping x.x.x.x
Where x.x.x.x is the Signaling Server ELAN network interface IP
address.
3
Ping the IP address of the Call Server. Enter the command:
ping x.x.x.x,3
Where x.x.x.x is the Call Server ELAN network interface IP address.
4
If desired, repeat step 3 for other devices connected to the network.
Configure two IP Phones to register to the Signaling Server on its temporary
node. These IP Phones must be provisioned on the Call Server. Refer to
Communication Server 1000E: Installation and Commissioning
(NN43041-310), Communication Server 1000M and Meridian 1:
Large System Installation and Commissioning (NN43021-310), or
Communication Server 1000M and Meridian 1: Small System Installation
and Configuration (NN43011-310) for the procedure appropriate to the
system. After provisioning, the telephones can call each other.
Installing a Signaling Server
End of Procedure
81C IGS to CS 1000M MG CP PII FNF Upgrade
Page 261 of 284
page